seriesoftubes/docs/plans/next-session.md
jvanvik b533f3baa8
Some checks failed
CI / test 1/4 (push) Waiting to run
CI / test 2/4 (push) Waiting to run
CI / test 3/4 (push) Waiting to run
CI / test 4/4 (push) Waiting to run
CI / build (push) Waiting to run
CI / test (push) Blocked by required conditions
CI / translations (push) Waiting to run
Container image / test (push) Waiting to run
Container image / publish (push) Blocked by required conditions
Auto-release / release (push) Has been cancelled
Plans: multiplayer phase 2 design, and what is left after this round
2026-11-07 01:12:23 +01:00

55 lines
4.4 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

# What is left (as of 2026-11-07)
Work in this fork, pushed to the `vanvik` Forgejo remote (never to `origin`). Built so far: the build standard, multiplayer
phase 1, dark mode (#80), IPv4 address space (#150), express fiber (#58) and satellite teleports (#83). Everything below is
planned or known, not built.
## Promised and not done yet
1. **Router model and line system set in one place only.** The build standard (`S.popStd.g`, `S.popStd.sys`) and two
standing-order settings say the same thing: the `routers` order's `model` (upstream 1e7638c) and the `optup` order's
`sys` (upstream 647e302). Neither ever steps down, so they do not fight, but a player can pick two different targets.
Plan: the Build standard sheet becomes the only place to pick them. The `routers` order reads its model from the
standard, and `optup` its line system (their lists turn into a line "from the build standard: X, change"); sanitize
moves an old `model`/`sys` setting into `S.popStd` when the standard has none.
2. **One owner per fiber for line systems and optics.** `std` (sys/opt targets: a quiet fiber, or a parallel link with
room) and `optup` (one full routing without the fiber, one a night) can each darken a fiber in the same shift. Let `std`
use `optup`'s check (`opsDarkOk`) for line-system swaps, or skip fibers `optup` is working on. Today `std` also holds
any fiber that carries an express with traffic; `opsDarkOk` would handle that case by itself.
## Next features
3. **Wave B: #97 co-op companies** (several players run one network with roles, budgets and approvals), host-authoritative
over the multiplayer server, and **multiplayer phase 2** (players as carriers in each other's simulations: transit,
peering, PNIs, shared fiber): design in `docs/plans/multiplayer-phase2.md`.
4. **Wave C: #144 directional traffic**, last and on its own: keep the totals, split them by traffic profile, utilization is
the busier direction. It comes after #58 because both touch link capacity (express channels now count too).
## Known limitations of what shipped
- **Multiplayer:** other players' POPs are not drawn on the map (no clean hook yet); cards are what each browser reports,
the server does not verify them; a save over ~60 KB sends only the card when the tab closes; the HUD chip in phone
landscape wider than 760 px was not measured. Behind a reverse proxy, run the server with `--trust-proxy`, or every
player shares one address for the rate limits.
- **Build standard:** the game menu has 8 tiles in a multiplayer game (7 otherwise), so the last row is not full; a wave
the standard just upgraded can still be handed back the same day by `decom` if a bigger parallel link carries it.
- **Dark mode (#80):** red error text on dark tinted cards is about 3.8–4.3:1 (bold, but below AA 4.5); the share card PNG
and the web manifest stay light; the WebGL map was checked by tests only, not by eye in a real GPU browser.
- **IPv4 (#150):** the intern does not manage addresses (optional in the issue); transfers are instant; lease-out income
is not in the investor revenue share; blocks granted to old saves can be sold after two years (a one-off windfall);
CGNAT annoyance costs refunds but does not slow broadband growth; the NOC window's address-space button does nothing.
- **Express fiber (#58):** splicing a whole fiber pair through a city was left out on purpose (every fiber end is a POP;
expresses cover the need); loss and MTU incidents on a fiber do not reduce the expresses on it; the fiber panel's
"n of max channels" line does not count express slots (the Express section does); regen sites added later do not charge
regen cards for express channels.
- **Satellites (#83):** no WISP zones, no satellite incidents (rain fade, sun outage), no footprints on the map, no
satellite tab in the drag-to-link window (ordering is from the city panel); GEO/MEO losses and prices are design
numbers; well-cabled islands (Wellington, Hobart) also count as "can be served"; MEO needs 5° elevation (10° would drop
416 pairs); Pitcairn's $120k satellite grant stays Pie-only.
## Housekeeping
- `npm run perf -- --browser` needs Chromium (`sudo pacman -S chromium`, then `PERF_CHROME=/usr/bin/chromium`); only the
jsdom benchmark has been run.
- Upstream release tags are not on `vanvik` yet: `git push vanvik --tags` if wanted.
- The merged worktrees under `.claude/worktrees/` and their `worktree-wf_*` branches can be removed.